Zones of Protection in Electrical Power Systems

The range within which an electrical protection device can detect a fault is termed as the device’s zone of protection. A short circuit fault occurs when a phase is connected to another phase or to ground via a low-impedance path. A short circuit results in the production of very high current magnitudes that can cause … Read more

Headworks in Hydroelectric Power Plant

The term Headworks is used in civil engineering for any structure at the head or diversion point of a waterway. Generally, it is smaller than a barrage and is used to divert water from a river into a canal or from a large canal into a smaller canal. In the case of hydroelectric power plants, … Read more

Role of Spillway in Hydroelectric Power Plant

dam-structure

The hydroelectric power plant reservoir is the enlarged lake behind the dam structure and is responsible for the storage of water. During the course of heavy rainfalls, the water flow exceeds the storage capacity of the reservoir. In order to avoid a dam against damages, surplus water should be discharged. A structure called spillways is … Read more

Humming in Transformers – Magnetostriction – What causes noise sound in Transformer

A transformer helps move electricity from one location to another. During its working, a transformer may vibrate or shake a little, and that tiny movement can cause a humming noise. The buzzing sound commonly heard from transformers or fluorescent light ballasts is caused by a phenomenon known as magnetostriction. This effect is a result of … Read more

Transformer MCQs Part 34

Electrical Engineering MCQ on Transformer No-load current in a transformer No-load current in a transformer Correct answer: 2. Lags behind the voltage by about 75° The winding of the transformer that has less cross-sectional area The winding of the transformer that has less cross-sectional area Correct answer: 1. High voltage winding During open circuit test of a … Read more

Recuperative vs Regenerative Preheaters

The air preheater is an auxiliary component of steam generating power plant. Recuperative and regenerative preheaters are two types of heat exchangers used in steam power plants to recover heat and increase the efficiency of the thermal power station. The major difference between these two types of preheaters lies in the way they store and … Read more

Critical Disruptive Voltage for Corona Formation

transmission-lines

When two conductors that are having a large spacing as compared to their diameters are subjected to an alternating potential difference, the atmospheric air surrounding the wires remains unchanged till a certain specific value of voltage. However, if the voltage surpasses this specific value a faint violet glow called corona appears around the conductors. This … Read more