Electrical Engineering MCQs on Induction Motor
In order to reverse the direction of rotation of a capacitor start motor while it is running
- Disconnect motor from supply and immediately reconnect it to supply with reversed connections of the main winding
- Disconnect motor from the supply till it stops then reconnect it to supply with reversed connection of main or auxiliary winding
- Reverse the direction of connection of the auxiliary winding and after motor comes to rest then connect auxiliary winding to the supply
- Reverse the direction of connections of the auxiliary winding and immediately connect it to supply
Correct answer: 2. Disconnect motor from the supply till it stops then reconnect it to supply with reversed connection of main or auxiliary winding”