Power System Protection MCQs Part 11.
Contents
- 1 The most dangerous fault in an alternator is
- 2 If failure of alternator takes place in alternator, then it
- 3 Most dangerous voltages in power systems are expected to be induced due to
- 4 Under normal conditions, a lightning arrestor conducts ___________ current to earth
- 5 A 3-phase induction motor whose stator is delta connected is carrying full load. If one of its fuses blows out then the motor
- 6 Which of following is correct in a transmission line
- 7 In an alternator the automatic protection relay is generally not provided for which of following faults
- 8 The impedance relaying scheme is used for protection of
- 9 A 3-phase delta connected induction motor is carrying too heavy load and one of its fuses blows out. Afterwards the motor
- 10 If one-phase of a 3-phase synchronous motor is short-circuited, it
The most dangerous fault in an alternator is
The most dangerous fault in an alternator is:
- Stator winding fault
- Failure of field
- Unbalanced load
- Prime mover failure
Correct answer: 1. Stator winding fault
If failure of alternator takes place in alternator, then it
If failure of alternator takes place in alternator, then it
- Draws some current from supply
- Runs as a synchronous motor
- Goes in inverted running mode
- All of these
Correct answer: 4. All of these
Most dangerous voltages in power systems are expected to be induced due to
Most dangerous voltages in power systems are expected to be induced due to:
- Resonance
- Lightning
- Insulation failure
- Arcing ground
Correct answer: 2. Lightning
Under normal conditions, a lightning arrestor conducts ___________ current to earth
Under normal conditions, a lightning arrestor conducts ___________ current to earth:
- Small
- Moderate
- Very high
- Zero
Correct answer: 4. Zero
A 3-phase induction motor whose stator is delta connected is carrying full load. If one of its fuses blows out then the motor
A 3-phase induction motor whose stator is delta connected is carrying full load. If one of its fuses blows out then the motor:
- Will continue running burning its two phases
- Will stop and carry heavy current causing permanent damage to its winding
- Will continue running without any harm to the winding
- Will continue running burning its one phase
Correct answer: 4. Will continue running burning its one phase
Which of following is correct in a transmission line
Which of following is correct in a transmission line:
- Inductance < Capacitance
- Inductance > Capacitance
- Inductance = Capacitance
- None of above
Correct answer: 2. Inductance > Capacitance
In an alternator the automatic protection relay is generally not provided for which of following faults
In an alternator the automatic protection relay is generally not provided for which of following faults:
- Overcurrent
- Overspeed
- Field failure
- All of these
Correct answer: 4. All of these
The impedance relaying scheme is used for protection of
The impedance relaying scheme is used for protection of:
- Alternators
- Bus-bars
- Transmission lines
- Transformers
Correct answer: 3. Transmission lines
A 3-phase delta connected induction motor is carrying too heavy load and one of its fuses blows out. Afterwards the motor
A 3-phase delta connected induction motor is carrying too heavy load and one of its fuses blows out. Afterwards the motor:
- Will stop and carry heavy current causing permanent damage to its winding
- Will continue running with one burning phase
- Will continue running without any harm to the winding
- Will continue running burning its two phase
Correct answer: 1. Will stop and carry heavy current causing permanent damage to its winding
If one-phase of a 3-phase synchronous motor is short-circuited, it
If one-phase of a 3-phase synchronous motor is short-circuited, it:
- Will overheat in spots
- Will not come upto speed
- Will fail to pull into step
- Will refuse to start
Correct answer: 4. Will refuse to start
Continue reading:
- Power System Protection MCQs Part 1
- Power System Protection MCQs Part 2
- Power System Protection MCQs Part 3
- Power System Protection MCQs Part 4
- Power System Protection MCQs Part 5
- Power System Protection MCQs Part 6
- Power System Protection MCQs Part 7
- Power System Protection MCQs Part 8
- Power System Protection MCQs Part 9
- Power System Protection MCQs Part 10